Where flow and pressure outgrow a threaded connection, the industry switches to a bolted flange. Two series, one dimension difference, and they do not interchange.

Code 61 vs Code 62

Code 61Code 62
StandardSAE J518-1, 3000 psi classSAE J518-2, 6000 psi class
Flange head thicknessThinnerThicker
Bolt patternSame nominal size, different headSame nominal size, different head
Interchangeable?No. The flange head and the clamp depth differ. Substituting one for the other will not seat correctly.
Typical dutyReturn and medium-pressure linesMain pressure lines on large machines

Components we supply

Sizes

Nominal sizes from 1/2" up through 2" and beyond, corresponding to dash -08 through -32. The flange size, the port size and the tube or hose bore are three separate numbers — quote all three.

The most common flange mistake

Mixing a Code 61 flange head with a Code 62 clamp (or the reverse). They bolt up, they look right, and they leak at the O-ring because the clamp does not sit at the correct depth. If a flange assembly leaks immediately after rebuild, check the code marked on both halves before looking anywhere else.

Pressure and confirmation

The code class gives the series pressure class; the actual working pressure of the assembly also depends on the flange material, the bolts and the O-ring compound, and it is defined by SAE J518. We confirm the rating for the exact parts on the order rather than quoting a generic number.